bioworldindia.in

Incubator Series

Standard Models

Bacterological Incubator-min

Bacterological Incubator-min

Technical Specification

Bacteriological Incubator 

Chamber Design

Double walled

Inner Chamber

Inner chamber made of stainless steel 304 Grade

Outer Chamber

Outer chamber made of mild steel and finished with powder coated.

Insulation

Insulation between inner and outer chamber is filled with high grade glass wool with a gap of 65mm thickness, to withstand maximum Temperature 60° C

Air Circulation Fan Motor

The motorized forced air circulation is provided at the back to maintain uniform temperature inside the chamber

Heater

Tubular air heater are made of high grade Kanthal wires of suitable wattage

Inner Glass Door

Inner full- length glass door is provided to view the samples without disturbing the temperature

Gasket

Rubber gasket and latch is provided for the door is provided for the door to avoid air leakage and temperature loss from Instrument.

Temperature Range

Ambient to 65°C

Temperature Controller

Microprocessor based PID temperature controller with dual display (Process value and set value), low and high limit setting with PT100 sensor and Timer control.

Temperature Resolution

0.1°C

Temperature Accuracy

± 1°C.

Temperature Uniformity

± 2°C.

Power Supply

230 Volts Single Phase 50Hz, AC supply

BOD Incubator-min

BOD Incubator-min

Technical Specification

BOD Incubator 

Chamber Design

Double walled

Inner Chamber

Inner chamber made of stainless steel 304 Grade

Outer Chamber

Outer chamber made of mild steel and finished with powder coated.

Insulation

Insulation between inner and outer chamber is filled with high grade glass wool with a gap of 65mm thickness, to withstand maximum Temperature 60° C

Wheels

The unit is mounted on a sturdy steel frame with caster wheels for easy movements to higher capacity 6,10,12CFT only.

Conditioning system Air

Circulation Fan Motor

The Double walled back of the instrument is provided with air circulation fans. The chamber is equipped with a vertical recirculating conditioning stream of air sucking from the top of the inner chamber and allows passing through the back side of the inner chamber duct and carrying heating/cooling/humidity which enters from the bottom of the chamber this process continuous to maintain uniformity throughout the chamber.

Cooling

. We use CFC free environmentally friendly refrigerant and compressors of Kirloskar/Tecumseh make, conforming to latest international standards and guidelines.

Inner Glass Door

Inner full- length glass door is provided to view the samples without disturbing the temperature

Outer Door

Inner stainless steel and Outer made of Mild steel finished with powder coated

Gasket

Rubber gasket and latch is provided for the door is provided for the door to avoid air leakage and temperature loss from Instrument.

Temperature Range

10°C to 60°C

Temperature Controller

Microprocessor based PID temperature controller with dual display (Process value and set value), low and high limit setting with PT100 sensor and Timer control.

Temperature Resolution

0.1°C

Temperature Accuracy

± 1°C.

Temperature Uniformity

± 2°C.

Power Supply

230 Volts Single Phase 50Hz, AC supply

Scroll to Top