Incubator Series
Standard Models
Bacterological Incubator-min

Technical Specification | Bacteriological Incubator |
Chamber Design | Double walled |
Inner Chamber | Inner chamber made of stainless steel 304 Grade |
Outer Chamber | Outer chamber made of mild steel and finished with powder coated. |
Insulation | Insulation between inner and outer chamber is filled with high grade glass wool with a gap of 65mm thickness, to withstand maximum Temperature 60° C |
Air Circulation Fan Motor | The motorized forced air circulation is provided at the back to maintain uniform temperature inside the chamber |
Heater | Tubular air heater are made of high grade Kanthal wires of suitable wattage |
Inner Glass Door | Inner full- length glass door is provided to view the samples without disturbing the temperature |
Gasket | Rubber gasket and latch is provided for the door is provided for the door to avoid air leakage and temperature loss from Instrument. |
Temperature Range | Ambient to 65°C |
Temperature Controller | Microprocessor based PID temperature controller with dual display (Process value and set value), low and high limit setting with PT100 sensor and Timer control. |
Temperature Resolution | 0.1°C |
Temperature Accuracy | ± 1°C. |
Temperature Uniformity | ± 2°C. |
Power Supply | 230 Volts Single Phase 50Hz, AC supply |
BOD Incubator-min

Technical Specification | BOD Incubator |
Chamber Design | Double walled |
Inner Chamber | Inner chamber made of stainless steel 304 Grade |
Outer Chamber | Outer chamber made of mild steel and finished with powder coated. |
Insulation | Insulation between inner and outer chamber is filled with high grade glass wool with a gap of 65mm thickness, to withstand maximum Temperature 60° C |
Wheels | The unit is mounted on a sturdy steel frame with caster wheels for easy movements to higher capacity 6,10,12CFT only. |
Conditioning system Air Circulation Fan Motor | The Double walled back of the instrument is provided with air circulation fans. The chamber is equipped with a vertical recirculating conditioning stream of air sucking from the top of the inner chamber and allows passing through the back side of the inner chamber duct and carrying heating/cooling/humidity which enters from the bottom of the chamber this process continuous to maintain uniformity throughout the chamber. |
Cooling | . We use CFC free environmentally friendly refrigerant and compressors of Kirloskar/Tecumseh make, conforming to latest international standards and guidelines. |
Inner Glass Door | Inner full- length glass door is provided to view the samples without disturbing the temperature |
Outer Door | Inner stainless steel and Outer made of Mild steel finished with powder coated |
Gasket | Rubber gasket and latch is provided for the door is provided for the door to avoid air leakage and temperature loss from Instrument. |
Temperature Range | 10°C to 60°C |
Temperature Controller | Microprocessor based PID temperature controller with dual display (Process value and set value), low and high limit setting with PT100 sensor and Timer control. |
Temperature Resolution | 0.1°C |
Temperature Accuracy | ± 1°C. |
Temperature Uniformity | ± 2°C. |
Power Supply | 230 Volts Single Phase 50Hz, AC supply |